Modify your browser's settings to allow Javascript to execute. See your browser's documentation for specific instructions. HP Customer Support. Select your model. How does HP install software and gather data? Search all support. Search help. Tips for better search results Ensure correct spelling and spacing - Examples: "paper jam" Use product model name: - Examples: laserjet pro p, DeskJet For HP products a product number.
Loading Results. Apache Log4j Update Please see this document here for current information regarding the Apache Log4j vulnerability. Need Windows 11 help? Already have an HP account? Select from the products you own. HP Scanjet Flatbed Scanner. Choose a different product series. Warranty status: Unspecified - Check warranty status Manufacturer warranty has expired - See details Covered under Manufacturer warranty Covered under Extended warranty , months remaining month remaining days remaining day remaining - See details Serial number: Product number: Warranty end date:.
Warranty status types. Warranty types. Verify product. It matches the product: Would you like to view the product details page for the new product? Unable to determine warranty status. We are unable to determine your warranty status for the product and serial number provided. Change your product.
Book Assistive Cover. Product Software Videos User Manual. CZUR Shine 2. Date: Size: North America. South America. Windows XP Version. Hard Disk The installation and operation of the program requires 1 G disk space. You can scan more images if the disk space is bigger. The recommended storage is 20G.
Update log 1. Optimized the effect of image processing. Fixed other bugs. Latitude -Top Left. Longitude -Top Left. Latitude - Right Bottom. Longitude - Right Bottom. Stored Rectangle. Edit Rectangle See New Rectangle above. Delete Rectangle. Set Avoid This determines whether a Department will be scanned or not. New Department See New Department. Programming Sites. Note: Not all options will appear for all sites. Set Site Quick Key. Set Attenuator. Set Filter. Delete Site.
Set Frequencies. New Site. The default setting is Wide. Wide or Narrow. P25 Systems. Explicit mode systems which comprise most systems in use include all information needed to determine voice frequencies on the control channel, leave all entries blank. The system will automatically detect the band plan and fill in the entries. Implicit systems need you to supply the systems band plan for the scanner to correctly determine voice frequencies.
Press Menu to return and repeat for each band plan as needed. The scanner will use the regular Motorola band plan. These systems require a Custom band plan. Custom band plans require that you enter both a lower and an upper base frequency value. The l ower base frequency or base is always the base frequency as provided in the Radio Reference Database. Use this Excel spreadsheet to calculate the upper base frequency value.
If you don't have Excel you can download and install a viewer here. The upper base frequency can also be found using the Band Plan Calculator at the online Wiki. Band Plan. Select Plan as needed for each Band Plan.
Set Base Freq. Set Offset. Set Frequencies This is where you program trunking frequencies for the Site. See also LCN Finder. Defaults to Search. Delete Frequency At Confirm Delete?
Set Modulation no P25 This setting selects the modulation used for the Site. The default setting is Auto. See also Site Modulation. Set Attenuator This setting controls whether the scanner attenuates signals on the Site by about 20dBs. See also Attenuation. Set Filter This allows you to set a Filter for the site. Set Avoid This determines whether a Site will be scanned or not.
Temp orary Avoids cancel when you cycle power. Search - The scanner opens squelch for any digital signal and displays the NAC being used blinking. Digital Waiting Time Motorola only This setting gives the scanner time to determine if channels on Conventional Systems have digital or analog transmissions.
Delete Site At Confirm Delete? New Site See New Site. In Scan Mode press Channel to hold on any channel. See also Edit Frequency or ID.
At Quick frequency save? The scanner will save the ID in a Department called Quick Save Department with no quick key assigned in the current system. Note: Not all options will appear for all channels. Set Delay Time. Set Priority. Set Channel Number Tag. You can also Avoid wildcard and partial IDs. Select Any for either or slot 1 or 2. If you are sure the channel is analog, set the channel to Analog Only. All - The scanner determines whether the audio is analog or digital.
Digital Only - The scanner will receive the channel only if it is carrying digital audio. Digital Code Option Conventional only. Search - the scanner searches and displays any digital code received. Analog Only - The scanner will only receive analog audio. Scroll to the desired DCS code you want present with the signal.
Set Modulation Conventional only This setting selects the modulation used for the channel. See also Channel Modulation. Set Attenuator Conventional only This setting controls whether the scanner attenuates signals on the Channel by about 20dB. Default is Custom 1.
Set Delay Time This sets in seconds the amount of time the scanner stays on a channel after the transmission has ended before moving to the next channel. A negative delay will force a resume after that number of seconds. The default setting is 2 seconds. Set Priority This sets the channel as a priority channel while scanning. Set Alert This setting controls when and how the scanner alerts you if the channel becomes active.
Set Avoid This determines whether a channel will be scanned or not. S ee also Channel Volume Offset. Delete Channel At Confirm Delete? New Channel See New Channel. Set Scan Selection. You must first enable each list here, before you can enable the quick key for the list or you will see 'Nothing to Scan' in the display.
Note: You will also need to set a location to enable the Full Database. The other way is using the number keys on the keypad. See also Selecting Quick Keys. Favorites Quick Key. Press Menu to return. System Quick Key. Favorites List. Manage Full Database. I nformation This will show the database version in the scanner. Using Startup Keys. You can program each of your Favorites Lists with a Startup Key so that when you power up the scanner and press the key number, just those Favorites List s assigned to the key will be enabled for scan.
Turn the scanner off. Press and hold the number key that corresponds to the startup key when you turn the scanner on. Continue holding the number key until the scanner display shows the number of the startup key configuration. The scanner then checks all Favorites Lists and:. Note : You can't cancel Startup Configuration, i.
Priority Scanning. Conventional Priority Scan When the scanner is scanning a Conventional System, it interrupts scanning, based on the Priority Interval and Max Channels settings, to check priority channels for activity. The more channels you have set to priority, the longer the interruption will be.
The Favorites List s and System s containing the priority channel s have to be enabled and not Avoided or the scanner will display Priority Scan No Channel. Conventional Priority DND The scanner checks priority channels, based on the Priority Interval and Max Channels settings, only when not receiving other conventional channels so there is no interruption in scanning with conventional systems. Priority ID Scan This function is similar to conventional priority although there is no interruption during the transmission.
Priority ID Scan is always on for a system if enabled in the system setting. Priority is checked in between transmissions, when the scanner is receiving the control channel, and during the channel delay period.
The scanner can only look for priority IDs in the trunked system it is currently scanning. Preemptive Priority ID Scanning For Motorola systems that have channel priority active on the system, if you flag a channel as priority and the system also has that TGID identified as a priority channel, the scanner will preempt any current transmission if the TGID becomes active.
The highest priority is for channels in System QK 0. The lowest priority is for channels in System QK Priority for channels in the same Department follows the order in which they were created.
Priority Options. Set Priority Sets the Priority Mode. You can also toggle these modes in Scan Mode by pressing Func then. Off - The Priority feature is off. Priority DND - The scanner checks conventional priority channels only when not receiving other conventional channels.
PRI appears in the display reversed -. Priority Scan - The scanner checks conventional priority channels. PRI appears in the display. Set Interval This sets in seconds how often the scanner will check the priority channels.
If there are more priority channels than the value you select, the channels are divided into more than one group and the scanner scans each group in turn.
Example: If you set the maximum channels to 20 and there are priority channels, the scanner checks those channels in groups of 20 and takes a total of 5 intervals to complete the priority scan.
Scanning Checklist. Contents Scanning Checklist: 1. Service Types for the channels you want to monitor must be set to On. Check or uncheck 'Monitor Full Database'. Custom 1 is needed for miscellaneous channels. Contents With previous scanners, you selected banks to scan.
See also Understanding Quick Keys. The scanner will not scan all Systems in one Favorites List and then move to the next List. Systems, Departments, and Sites with the same QK are scanned in order of creation.
Conventional Channels in Departments are also scanned in order of creation. The Database is scanned next, in order of creation. The scanner scans a system for the duration you set using the System Hold Time option.
For trunked systems, the scanner moves to the next system after the hold time expires, the current transmission ends, and the channel delay expires. Conventional systems operate similarly, but all Unavoided channels are scanned at least one time regardless of the hold time setting. IDs are not really scanned. The scanner checks for any activity in the trunking system and:. Notes: You can press Menu or Avoid to cancel any entry. If you make a mistake entering numbers, you can use the scroll control to backup and correct entries.
Example: 3. Example: 0. Press Avoid to exit the QK Navigation screen, or. Notes: Leading 0's required to view complete status. You can press Menu or Avoid to cancel any entry. Scan Menu Contents. FLQKs - Press 0. FLQKs - Press 1. FLQKs - Press 2 , etc. Toggle Display Modes. While scanning, press Replay. Turn the Scroll Control to select recordings. Note: Replay is not available when recording is enabled.
See also Replay Options. While scanning, press Func then Replay. Review Recordings. While scanning, press and hold Replay. Note: ID Search is not available with the Database. Scan Hold. P ress Channel softkey3 to hold on a Channel. You can now scroll all Channels. Press Channel softkey3 to release Channel Hold. Press Dept softkey2 to pause for 2 seconds then hold on any Department. Department is reversed in the display for Pause Mode Double press Dept softkey2 to hold without a pause.
Press Dept softkey2 then quickly scroll to any Department in Pause Mode. Double press Dept softkey2 to release Department Hold. Press System softkey1 to pause for 2 seconds then hold on any System. System is reversed in the display for Pause Mode Double press System softkey1 to hold without a pause.
Press System softkey1 then quickly scroll to any System in Pause Mode. Double press System softkey1 to release System Hold. Press Func then Site softkey2 to hold on any Site in the current System.
To Permanent Avoid press Avoid twice quickly. To Permanent Avoid press Dept then quickly press Avoid twice. To Permanent Avoid press System then quickly press Avoid twice. Press Func then Site to release Site Hold. Store a Channel from the Full Database. Add to Favorites List. At Are you sure? New Department Then see Data Naming. After storing the ID, you will be at the Channel Options menu to complete the settings for the new channel.
Store a Search Frequency Search with Scan. Then see Storing Search Frequencies. Conventional Channel Attenuation - Press Channel to hold on the channel. Press Func then 4 ATT to toggle attenuation. Press Channel to resume. Press Func then Site softkey2 to resume. Global Attenuation - Press Channel to hold on any channel. Press Func then press and hold 4 ATT to toggle global attenuation.
ATT blinks in the display when global attenuation is on. Press Func then MOD softkey3 to toggle modulation. Press Channel to release Channel Hold.
Press Channel to hold on any Channel. Press Channel to release Channel hold. Select Service Types. Press Channel to hold on the channel. Press Func then 7 IFX to toggle on or off. View Repeater Frequency for a Conventional Channel. Press Func then press and hold 8 REV. Channel Volume Offset.
Scan Priority Modes. Weather Alert Priority. Press Channel to hold on any channel. Press Func then 6 WX to toggle on or off. Close Call Modes. See also Set Your Location.
Press to Scan soft key1 to exit. Using Number Tags. If two Favorites Lists have the same number tag, they will be selected in sequence. The first time you select the number tag, the scanner will go to the first Favorites List assigned to that number tag; if you select the same number tag again, it will go to the 2nd Favorites List assigned to that number tag, and so on.
The same rule applies to System and Channel number tags So don't start with 0 for all your systems and channels. Enter the Favorites number tag,. Examples: 2. Press Func then Avoid and scroll to select each Avoid.
Press Avoid to return. Press Channel to release Hold Mode. Clear Scan Avoids in Current System. Press Channel to hold on any channel in the current System. Press and hold Avoid. Press Channel to hold on any channel in the current Favorites List or the Database.
Press Func then press and hold Avoid. At Stop Avoiding All Systems? Custom Search by Search Quick Key. Then see Searching.
Quick Search at Current Frequency. Press Channel to hold on the frequency. At Quick Search? Weather Scan. Press Func then press and hold 6 WX. Using Filters. If 'Auto' is selected, conventional scan and search speed will be greatly slowed, as every frequency on which a signal is not detected on first pass will be rescanned using the inverted HPF setting.
When you pick this setting, the filter becomes weaker for interference on a nearby frequency. However, the linearity of the IF can be maintained even when there is strong interference within the band, and the reception may be improved in some cases. They work differently for different transmissions and locations so one setting may work for one person and not the other for the same system. Choosing the right filter may improve performance for some systems.
You can set filters only for conventional Departments and trunked Sites. The Global setting will set all Searches, Departments, and Sites which can then be overridden for each Search and Close Call , Department option , or Site option if desired. With that said, all I can do is refer you to interesting links that may help you out. Using Filters What is the difference with all the filters in the sds scanner? Using a GPS.
This frees you from having to manually enable and disable Departments and Sites as you change locations. You should select a baud rate of bps for the serial port in the Set Your Location menu. A good application of this feature would be to set the longitude and latitude for each multi-site system transmitter as usually you can receive at least a handful in any given location.
Set the scan range to 0 for your location and the scanner will automatically Avoid or Unavoid Sites when in and out of range. Both sites list the latitude, longitude, and height of the antenna and both sites can map the exact location for you.
Note: If you unplug your GPS device or it loses reception to satellites, the scanner will use the last known location as the current location. Using Analyze. Analyze allows you to view signal strength, signal quality and activity on sites in trunked systems. There is a 'Power Plot' feature that allows you to view frequency strength for up to 16 seconds.
Each site and system has to be enabled for scan QK on, not avoided for analyze to use them. The display will show the control channel signal strength, the control channel decode quality, and the level of system activity. It will also overwrite any existing LCN numbers if you save the results.
If the control channel signal is lost for more than 10 seconds, the LCN finder will reset. This function depends on the system having voice traffic to determine the correct LCNs.
The more traffic, the faster it will complete. Best results are achieved when the site is not extremely busy. For a Capacity Plus system to find another LCN, there must be at least two simultaneous comms on the system. The scanner will notify you when all LCN number are found. If the Finder does not finish or you want to exit, press to Scan softkey1 to save what you have. Pressing Func then Menu will return you to the Analyze Menu. Because the process uses statistical correlation it can result in false finds, especially on a busy site.
Running the LCN Finder several times is recommended. Discovery Mode. Trunking Discovery Mode allows you to monitor a trunked radio Site for channels not currently in the database. It can automatically record audio and log newly discovered channels for later review and identification. Conventional Discovery Mode lets you monitor a range of frequencies that are not already known to be in use in your area. This includes frequencies used conventionally as well as in trunked radio systems.
It can automatically record audio and log newly discovered channels for later review and identification so that you can more easily identify the users. Both modes allow you to listen while discovering, have the option to compare hits to the Database, and log all hits or just new hits.
You can create and save several sessions with different settings. Every time you start a session you create a 'Run '. Review Discovery allows you to review the Run results, resume Runs, or restart saved Discovery Sessions. Before using this mode, set your location and location range, and enable the Database or Favorites Lists to use for Discovery.
New Session. Conventional Discovery. T r unking Discovery. Notes: To select the trunked system: 1. The trunked system must be enabled in 'Select Lists to Monitor', 2. The service types for channels in the system must be enabled. Session Options. Edit Session Name. Set Logging Set Auto Store.
Set Limit Frequencies. Set Compare to Database Delete Session. Set Record Duration Change System. Set Delay. System Info Review Discovery. Edit Session Name This allows you to name a Session. Set Limit Frequencies Conventional Only This sets the lower and upper frequencies for the conventional discovery session.
Set Lower Limit - Enter the lower limit. Set Upper Limit - Enter the upper limit. Set Modulation Conventional Only This sets the modulation for the conventional discovery session. Set Step Conventional Only This sets the step size for the conventional discovery session. Set Delay This sets the Delay when monitoring a site or frequencies. Set Logging This will log all hits or just new hits.
All or New Only. Set Compare to Database Select On to compare hits against all channels currently enabled Database and Favorites Lists and the scanner will not record hits for known channels. Only new channels will have audio recorded if recording is enabled. Select Off to treat all hits as new channels. Set Record Duration This sets the max record duration of the transmission. System Info Trunking Only This will show you the Database used, the system type, system used, and site used.
Delete Session This deletes the session. Input System Name. Notes: To select the system: 1. The service types for the channels in the system must be enabled. Select Site. S croll to the Site to use for the session. Start Discovery Before using this mode, set your location and location range, and enable the Database or Favorites Lists to use for Discovery. To Exit Discovery Mode press to Scan soft key1.
Press Avoid to Avoid a hit. Press Menu to stop and review the Run information. See Review Discovery. Review Discovery. In Review Discovery mode, you can review the results of discovery mode runs, resume runs, or restart saved discovery sessions. You can download and review sessions in the Sentinel software. Review Run Results. Summary - List by each frequency. Detail - List by each hit. Restart this Run - Delete all log files. Resume this Run - Continue without deleting log files.
Delete this Run. Confirm Delete? Rename this Run. Run Information. This will show you the location info, range, the Database used, the system used, system type, site used, and other Session options.
Freq Avoids. Broadcast Screen. Digital Waiting Time. Repeater Find. Temporary Avoids are noted with a T. Broadcast Screen Automatically ignores transmissions that are on common broadcasts, paging systems, and other annoyance radio sources during Custom Search, Quick Search, or Close Call Search.
You can select common bands you want to ignore or program custom bands. The default setting is Pager On.
0コメント